Physiotherapy Electrode

What Is Physiotherapy Electrode

 

 

The physiotherapy electrode is making by non-woven cloth,carbon layer, sticky gel conductive, release film and wire connected with the outside world. And a temperature sensor is installed between the gel insulating sheet and the carbon sheet, and both ends of the temperature sensor are connected with the terminal through a wire. The heating physiotherapy electrode has the function of temperature control, and the inside of the heat dissipation grid, can fully emit local heat, more convenient, comfortable and safe to use.

Advantages of Physiotherapy Electrode

 

 

Convenient and easy to use
Physiotherapy electrode pads are easy to use. You only need to stick the electrode pads on the treatment area for treatment. It does not require any surgical incision or injection of drugs, reducing the patient's pain and discomfort.


Significant curative effect
The therapeutic effect of physiotherapy electrode pads is significant, which can relieve pain, promote blood circulation and metabolism, and accelerate tissue repair and recovery.


Reusable
Physiotherapy electrode pads can be reused, just need to pay attention to cleaning and disinfection. Compared with disposable treatment equipment, physiotherapy electrodes save medical costs and are more environmentally friendly.


Wide range of application
Physiotherapy electrodes can be used to treat various diseases, such as musculoskeletal pain, neurological diseases, heart disease, respiratory diseases, etc.

First 12 Last 1/2
Why Choose Us

 

Our Factory and Workshops

In 2019, our company produced 2.5 million disposable electrosurgical pens, 1.5 million negative plates, and 800,000 skin staplers. We regularly attend major exhibitions such as Arab Health in January in the United Arab Emirates and Medica in November in Düsseldorf, Germany.

Main Products

Our main products include disposable surgical electrodes (also known as electric knife pens, electric knife heads, or electric knife handles) and disposable neutral electrodes (also known as negative plates). Our products are registered under the "Chengguang" brand. Formerly known as Huatong Medical Devices Co., Ltd., the company started trial production in 1995 and has over 20 years of experience in the field of medical high-frequency equipment.

Fast and Efficient Services

Source from us to receive samples within 7 days and confirmed orders within 30 days. With our professional supply chain and a monthly output capacity of 300,000 pieces, we are well-equipped to handle large-volume orders. We welcome customers to visit our office, showroom, and workshop for further details. OEM services are also available.

Our Sales Team

Our professional export sales team provides a one-stop solution service, including order follow-up, quality control, container loading, shipping arrangements, and document preparation.

 

What Effect Does Physiotherapy Electrode Thickness Have on Treatment ?

 

 

Physiotherapy electrode is a kind of anti-fouling, deodorization, absorption, inhibition products, with far infrared rays, can better promote blood circulation, after pasting the product, To a certain extent, it can also kill diseased cells, and the electrodes are so soft and flexible that they are suitable for any part of the body, even the finger, which can be completely wrapped, leaving no gap, and the finger can bend freely. With antifouling, deodorization, absorption, inhibition. With far infrared rays, can better promote blood circulation. Pasted in a certain extent and range can kill the diseased bad cells. The use of soft, elastic, can be attached to any part of the body, it can wrap the whole finger without pores, fingers can still bend freely. Various styles of electric patch, suitable for all people in need. Good electrical conductivity, electrical impedance per square inch is only about 20 OHM almost similar to metal, and electrical impedance is uniform. In use, do not worry about the use of physiotherapy electrodes due to resistance points for attention. Pay attention to clean the skin before use, the electrical conductivity of the human skin is relatively poor, if there is oil, dander and other attachments on the skin, it will affect the performance of the physiotherapy electrode, thus affecting the performance of the device, so we must clean the skin before use. The electrode itself has a conductive layer, directly paste the black conductive layer on the skin to ensure close contact with the skin, so that the current evenly contact with the skin, flow to the human body. Conductive self-adhesive plus water care, can make the adhesive sheet to maintain good electrical conductivity and viscosit. Structure performance: keep the humidity of the electrode, enhance the conduction effect. This product is composed of connector, electric cloth, water based polymer gel agent, essential oil and so on. Suitable for medium and low frequency physiotherapy instrument and therapeutic instrument. Take out the electrode, uncover the protective film, and apply the electrode to the site to be treated. Through the stimulation and absorption of drugs on acupoints and affected skin, through the conduction of meridians, it can dredge veins, regulate zang fuorgans, coordinate Yin and Yang, and achieve the purpose of internal and external treatment, disease prevention and treatment. To speed up the percutaneous penetration of drugs and increase the amount of drug introduction. Wide range of application, can easily penetrate macromolecular drugs. Wide indications, safe and reliable, no pain and side effects, no damage to healthy tissue. Multiple effects compound, promote each other, easy to operate.

 

Precautions When Using Physiotherapy Electrodes

 

The electrode is attached to the corresponding treatment site of the human body, so that the positive and negative poles of the therapeutic instrument are connected, and the pulse wave generated by the therapeutic instrument is passed through the self-adhesive electrode to simulate acupuncture and massage therapy like countless electric needles. Self-adhesive electrode sheet can meet the needs of various body surface (acupoint) electrical stimulation therapy. It is fast and convenient to use, thin and soft texture, close adhesion, reliable bonding, uniform conduction, comfortable and safe treatment, no stinging, no burn, properly stored, can be used repeatedly. Tear the protective film on the adhesive before use. Attach the self-adhesive electrode to the part that needs physiotherapy or the corresponding point and press tightly. After physiotherapy, separate the electrode from the wire and cover with a protective diaphragm. When the adhesive force is insufficient, the surface can be cleaned with clean water. After the dirt is removed, part of the adhesive force can be restored. Self-adhesive electrode is consumable parts, please take good care of use, storage temperature is 10℃-40℃, avoid direct sunlight. The use of electrodes should first clean the skin and remove the grease and sweat stains on the skin surface, which can make the physiotherapy effect better and prolong the use of electrodes. Physiotherapy electrode according to its role and effect is not the same, the replacement time is different. The length of time the physiotherapy electrodes are placed in the body depends on the pre-existing condition. Electrocardiogram monitoring electrode placement time is too long, will lead to local allergy, itching performance. If it needs to be placed for a long time and itching is obvious, some local treatment can be done on the skin to reduce itching symptoms. Physiotherapy electrode patch paste and replacement of disposable electrode patch method. Clean and treat the local skin on the chest, remove grease and stain with 75% alcohol, and shave the chest hair on the electrode site if necessary. Select the physiotherapy electrode connect it to the Japanese photoelectric monitor, paste it firmly, and the position is required to be accurate to prevent the electrode from falling off. The physiotherapy electrodes should completely avoid the precardiac area and muscular parts of the chest wall. Should be in close contact with the skin, sweating timely replacement, regularly change the position of the sticking electrode, to prevent skin damage.

 

 

Physiotherapy Electrode Pad Classification

The electrode sheet can be divided into different electrodes according to different standards, such as: self-adhesive electrode sheet, if according to the material can be divided into PET self-adhesive electrode pad, silica gel self-adhesive electrode pad, silica gel self-adhesive electrode pad, other buttons self-adhesive electrode pad. Silicon gel electropad can be divided into water absorption electrode, heating electrode pad, conductive electrode etc. The electrodes are consumable, so they have a lifespan, and it is best to wash the skin with soap (alcohol is fine) before using them. By cleaning the skin to achieve better effect, improve the use of electrodes. After each use, put electrodes back original packaging bags, placed the shade, should not be placed the sun exposure. If there are a few dry electrodes, can use a few drops of water is it wet doing this can increase the service life of electrodes room temperature can be stored two years of electrodes as part of the medical equipment accessories consumables, it generally consists of three parts, the top layer of the is different capable person, is in the middle of viscose, the last one is from type membrane. At the same time according to the top of the material is different, divided into PET; Silica gel; Non-woven fabric; Foam other materials of electrodes, etc. According to the craft that make different, divide again button electrode plate and pin type of electrodes. Physiotherapy electrodes are only suitable for low and medium frequency instruments.

TENS Electrode Pads

 

Tell You the Requirements for Using Physiotherapy Electrode

 

 

The electrode sheet of medical equipment has excellent conductivity and strong adhesion, which is suitable for different groups of applications, and the actual effect is remarkable. Reliable, reusable and other characteristics, the recent marketing of ultra-low-cost marketing products: medical equipment electrodes, physiotherapy electrodes, hot electrodes, PET self-adhesive electrodes, breast enhancement electrodes, conductive electrodes, Non-proof cloth electrode pads, slimming electrode pads, silicone rubber electrode pads, different shapes can be customized according to the needs of customers, there are eight-shaped, fenugreek, square, round, oval, 60*80 with wire electrodes Sheet. The electrode sheet of medical equipment has the characteristics of excellent conductivity, strong adhesion to the skin, reliability, and can be reused many times. It is suitable for different groups of applications, and the actual effect is remarkable. Recent marketing of marketing products: medical equipment electrodes, physiotherapy electrodes, hot electrodes, PET self-adhesive electrodes, breast enhancement electrodes, conductive electrodes, non-proof cloth electrodes, slimming electrodes, silicone rubber electrode pads, with different shapes, can be customized according to the needs of customers, such as figure-eight, fenugreek, square, round, oval, and 60*80 wire electrode pads. Disposable acupuncture and physiotherapy electrode pad packaging is damaged, when the electrode pad is dry, it is not suitable for application to prevent burning. If you feel too irritating during application, such as obvious stinging or burning sensation on the skin, you must reduce the compressive strength or temperature of the physiotherapy device. Maintain the environmental humidity of the electrode sheet and improve the actual effect of conductivity. It has anti-fouling, deodorization, digestion and absorption of endotoxin, and inhibits germs. With far-infrared radiation, it can promote the blood circulation system more strongly. It can kill the diseased bad body cells at a certain level and range. The application is soft and malleable, and should be attached to all positions of the human body. It can wrap all the fingers without porosity, and the fingers can still be easily bent. There are various styles of electric patch, suitable for all necessary groups. Good conductivity, the electrical characteristic impedance is only about 20OHM per square inch, basically similar to the metal material, and the electrical characteristic impedance is well-proportioned. In the application, there is no need to worry that the uneven current amount caused by the asymmetry of the electrical characteristic impedance will sting the skin.

Size and Shape Are Factors to Consider When Choosing the Right Physiotherapy Electrode

 

Electrodes are central to all branches of electrotherapy. Their role is to facilitate the transmission of electric signals into the body. They do this by achieving a sound electrical contact between the patient’ s skin and the device generating the electrical signal. This device could be a TENS machine, ultrasound unit, etc. Probably the most important factors to consider in choosing the correct electrode is size and shape. The correct size in any particular case depends on the area of the body that will be treated. The main objective will be to make good electrical contact throughout the surface of the electrode. You may find that a smaller electrode works better on more contoured body areas. The shape of the electrode can also be an important factor in ensuring good electrical contact. Depending on the specific area being treated, a round electrode may be a better choice than a square one, or vice versa. 2’ x 2’ square are a good choice for localized pain control, especially in highly contoured areas like the elbow or knee. The small size of the electrode means that it can achieve high conformity to the skin even in areas such as these. This (or similar) electrode sizes are usually used in sets of 4. Typically, you buy an envelope of electrodes consisting of 10 sets of 4. 2’ round like the 2’ x 2’ square electrodes, these are a great option for micro targeting small painful areas. They can actually be oval shaped in addition to circular. They can provide conformity in even more highly contoured areas than the 2’ x 2’ square size. Butterfly shaped electrodes are useful on large flat areas where conformity is not necessarily an issue. For example, they can be used effectively for lower back pain. Another popular shape is a long rectangular one. They are suited for body areas such as the spine. They are also use for areas such as the, calf or thigh. They can be simply wrapped around these parts to provide optimum coverage simultaneously with excellent conformity. Besides the correct size and shape, you should try to choose electrodes that offer. Excellent adhesion and conformity to the skin. Reusability with no loss of conductivity. A cloth backing that allows the electrode to more easily follow the contours of the skin. A thick hydrogel layer that makes the electrodes easy to secure and that provide good current distribution. A robust connection mechanism with the device supplying the current.

 

Tips for Physiotherapy Electrode Manufacturing and Design

 

 

Modern physiotherapy electrodes are often made using conductive hydrogel or hydrocolloid material, which are easy to remove and gentle on the skin. Converters will laminate to one side of the hydrogel or hydrocolloid for additional stability. Then, they’ ll die cut the part component into the final shape, package it, and send it off for use. Each patient demographic has skin that behaves a certain way, which you’ll need to consider to have a project with the best functionality. For instance, neonatal and elderly patients are likelier to possess thin, delicate skin requiring softer, gentler products. Using the wrong type of adhesive on either of these age groups could result in skin damage that worsens the existing condition. Medical tapes for sensitive skin will cling onto the skin but peel easily upon removal, mitigating the risk of damage. Even a light-release acrylic is still tight compared to silicone skin adhesive. For this reason, gentle silicone adhesives are more suitable for patient demographics at a higher risk of torn skin. Medical products are precise by nature, so customers tend to know the exact materials and specifications they need. However, your product price can vary considerably based on the materials you choose. When it comes to the price of skin adhesives, silicone is often 2-3x more expensive than acrylic. Although you have an incredible electrode pad design, a large piece of your product’s success still depends on its manufacturing feasibility. You can prepare yourself for a smoother process by seeking expert advice and assistance in that area. Flexible material converters will be able to advise you on critical production factors such as die cut tolerances and clean room usage. Using materials like conductive hydrogel makes it challenging to hold die cut tolerances. Every die cut design has tolerances that dictate the acceptable deviation range for each part measurement. Your design tolerances might not be an issue if your design is a simple shape (which many electrode pads are). Still, because each product is different, the tolerances may be highly specific or challenging to achieve. Another cost-relevant factor to consider is whether your part needs to be processed in a particle-reduced environment like a manufacturing clean room. Physiotherapy electrodehave adhesive laminated onto one side for skin adhesion.

productcate-1-1

 

Our Factory

Jinhua Huacheng Medical instrument Co., Ltd. is located in Jinhua, the central city of Zhejiang, which was founded in 2013. It is the key enterprise of medical devices in Jinhua City, and is allowed to produce second category of 6825 medical high-frequency equipments, produce and sell second category of 6864 medical health materials and dressings. Main products of the company are disposable surgical electrode (also known as electric knife pen, electric knife head, electric knife handle), disposable neutral electrode (also known as negative plate). The registered trademark of our products is "Chengguang" brand. The company formerly known as Huatong Medical Devices Co., Ltd. and trial produced in 1995, which has over 20 years experience in the field of medical high-frequency equipment. The operation electrode and neutral electrode of our company is sophisticated, quality reliable and various kinds, which is suitable for various types of high frequency host and for surgery, gynecology, neurosurgery, cosmetology department and other professional departments. It receives wide and excellent reputation in the market and among customers.

 
Certificate
 

 

productcate-1-1

productcate-1-1

productcate-1-1

productcate-1-1

 

 
FAQ
 
 

Q: What are physiotherapy electrodes?

A: Physiotherapy electrodes are medical devices used in electrotherapy to deliver electrical stimulation to specific areas of the body for therapeutic purposes.

Q: How do physiotherapy electrodes work?

A: Physiotherapy electrodes work by transmitting electrical impulses from an electrotherapy device to the body, stimulating nerves and muscles to promote pain relief, muscle relaxation, or muscle contraction.

Q: What are the different types of physiotherapy electrodes?

A: There are various types of physiotherapy electrodes, including reusable electrodes, disposable electrodes, self-adhesive electrodes.

Q: Why are physiotherapy electrodes important in rehabilitation?

A: Physiotherapy electrodes play a crucial role in rehabilitation by facilitating muscle strengthening, pain management, range of motion improvement, and functional recovery in patients undergoing physical therapy.

Q: What are the components of a physiotherapy electrode?

A: The components of a physiotherapy electrode typically include a conductive gel or adhesive, a backing material, a connector for attachment to the electrotherapy device, and a conductive surface for electrical stimulation.

Q: How are physiotherapy electrodes applied to the patient's body?

A: Physiotherapy electrodes are applied to the skin over the targeted muscle or area using adhesive or gel to ensure proper contact and optimal delivery of electrical stimulation during therapy sessions.

Q: Can physiotherapy electrodes cause skin irritation?

A: In some cases, physiotherapy electrodes may cause skin irritation or allergic reactions due to the adhesive or gel used, but selecting hypoallergenic electrodes and proper skin preparation can help minimize these risks.

Q: How long can physiotherapy electrodes be used during a therapy session?

A: Physiotherapy electrodes can typically be used for the duration of a therapy session, which may range from a few minutes to an hour, depending on the treatment protocol and the patient's condition.

Q: Can physiotherapy electrodes be used in combination with other modalities?

A: Physiotherapy electrodes can be used in combination with other physiotherapy modalities such as ultrasound therapy, heat therapy, or manual therapy to enhance treatment outcomes and address multiple aspects of rehabilitation.

Q: What safety features are present in physiotherapy electrodes?

A: Physiotherapy electrodes may include safety features such as latex-free materials, hypoallergenic adhesives, and skin-friendly gel formulations to minimize skin irritation, allergic reactions, and discomfort during therapy.

Q: Are physiotherapy electrodes compatible with all electrotherapy devices?

A: Physiotherapy electrodes are designed to be compatible with a wide range of electrotherapy devices, but healthcare providers should ensure proper electrode selection and connection for optimal treatment outcomes.

Q: How do physiotherapy electrodes impact muscle rehabilitation?

A: Physiotherapy electrodes play a vital role in muscle rehabilitation by promoting muscle activation, strengthening, coordination.

Q: Can physiotherapy electrodes be used for neuromuscular re-education?

A: Physiotherapy electrodes are commonly used for neuromuscular re-education to improve muscle control, coordination.

Q: How do physiotherapy electrodes impact functional recovery in patients?

A: Physiotherapy electrodes support functional recovery in patients by facilitating muscle activation, motor control, strength gains.

Q: Are physiotherapy electrodes single-use or reusable?

A: Physiotherapy electrodes are available as both single-use disposable electrodes and reusable electrodes, with disposable electrodes being more common in clinical settings for infection control and convenience.

Q: What are the advantages of using self-adhesive physiotherapy electrodes?

A: Self-adhesive physiotherapy electrodes offer the advantage of easy application, repositioning flexibility, reduced skin preparation time, and improved patient comfort during electrotherapy sessions.

Q: How do healthcare professionals select the appropriate physiotherapy electrodes for a specific patient?

A: Healthcare professionals select the appropriate physiotherapy electrodes based on factors such as the treatment goals, the targeted muscle group, the patient's skin sensitivity.

Q: Can physiotherapy electrodes be used in pediatric patients?

A: Physiotherapy electrodes can be used in pediatric patients for muscle stimulation, pain management.

Q: What are the considerations for storing physiotherapy electrodes?

A: Physiotherapy electrodes should be stored in a cool, dry place away from direct sunlight and moisture to maintain their adhesive properties, gel integrity.

Q: How do physiotherapy electrodes impact the effectiveness of electrotherapy treatments?

A: Physiotherapy electrodes play a critical role in the effectiveness of electrotherapy treatments by ensuring proper electrical stimulation delivery, muscle activation, pain relief.

As one of the most professional physiotherapy electrode manufacturers and suppliers in China, we're featured by quality products and competitive price. Please rest assured to wholesale customized physiotherapy electrode made in China here from our factory. For pricelist and quotation, contact us now.

Electrode For ECG Monitoring,

whatsapp

Phone

E-mail

Inquiry

Bag